ABASE CONDITIONS
Fairly level; remove surface oil, mortar dust and dust. Grounding electrodes installed at depths below 3 m are required. Medium-intensity shot blasting recommended.
BDESIGNED APPLICATION
Surface and body resistance in two classes: 1×10⁶–10⁸ Ω·cm and 1×10⁴–10⁶ Ω·cm. Suited to environments with high cleanliness demands where static sparks could cause quality or safety incidents, e.g. electronics plants, flour mills, chemical plants and oil/gas filling and packaging plants.
CSYSTEM SECTION


The above shows a typical system section. Every customer's environment and requirements are different — after a full site survey we provide a tailored construction plan. Contact us for a custom proposal.